The RBC5000 is designed to be extremely user friendly and offer excellent power to weight and size ratio. The RBC5000 is over powered; this means you can guarantee the power this unit offers. The RBC5000 provides up to 1600, 2000 or 3000 Peak Amps, it comes in an IP54 case and is capable of working at temperatures from -20°C to +50°C.
The RSC5000 is designed specifically for Aircraft and can easily be moved around the hanger. Other variants are available of the RSC5000 and units can be built to specification. Contact our sales or technical team for advice.
- 600 Amps continuous.
- 2000 Amps peak.
- All-Weather IP54. Supplied on heavy duty castors, trailer mounted for ramp use, or static unit for installed use.
- High overload capability for engine start.
- Low acoustic noise.
- Simple operation with analogue indication.
- Lights for machine Status.
- Illuminated panel for around the clock operation.
Voltage | 380 TO 460VAC, 3-Phase with or without neutral |
---|---|
Frequency | 50Hz or 60Hz, +/- 6% |
Current Harmonics | EN61000-3-12 EMC – Harmonic Limits |
Power Factor | 0.93 |
Inrush | Limited to 50 Amp |
Connections | 63 Amp, 10 metre, 5 core cable with BS4343 plug or H/W |
OUTPUT: | |
Voltage | 28.5V DC |
Voltage Regulation | Steady-state: +/-5%, dynamic 0-100% step load: +/-15% recovering to steady-state within 50mS |
Peak Amps | 600 Amps continuous and 2000 Amps peak |
PROTECTION: | |
Input Protection | 63 Amp circuit breaker with current limiting |
Thermal Overload | Thermal sensors located in main rectifier, transformer and power module. |
SYSTEM: | |
Ambient Temperature Range | -20 to 50 deg C |
Humidity | Less than 90% non condensing |
Altitude | All specifications quoted at < 2000m above sea level |
Acoustic Noise | Typically 65dB |
Efficiency | 85% to 95% |
EMC | EN61000-3-12 EMC – Harmonic Limits EN61000-6-2 EMC – Immunity for Industrial Environments EN61000-6-4 EMC – Emission Standards for Industrial Environments |
Casing | Zinc plated steel, powder coated RAL No. BS3020. Size 103cm High x 71cm Wide x 110cm Deep without castors |
Case Rating | IP54 EN60529 – IP Ratings for Enclosures |
Meters | Analogue readout for output Amps and Volts |
Panel | Status lights for input and output conditions, and alarms |
VARIENTS | |
Castor Version | Size 118cm High x 71cm Wide x 110cm Deep |
Tow Bar | 1200mm long with 50mm eye (with trailer version only) |
Stationary Version | Size 118cm High x 71cm Wide x 110cm Deep |
Volts DC | 28.5 |
---|---|
Peak Amps | 600 |
Maximum S/C Amps | 2000 |